Sinocare Gold AQ Plus blood glucose meter
LUNULA nanoTM patent blood sample applying technology, which can provide you with
the most accurate blood sugar test results
-
Intended Use
The Gold AQ Plus Blood Glucose Monitoring system is intended for use in the quantitative measurement of glucose in human whole blood taken from the fingertip (capillary) or from the vein (venous) or from the artery (arterial). The hematocrit (HCT) test range is 20% - 70%, which applicable to pregnant women and anemia people.
-
Test Principle
The measurement of Gold AQ Plus blood glucose meter is based on of electrical current caused by the reaction of glucose with the FAD glucose dehydrogenase on the electrode of the gold strip, which is more stable and accurate.

-
About the Gold AQ Plus Blood Glucose Test Strip
- 99.99% gold electrode, a conductivity of 1,400 times than carbon electrode.
- LUNULA nano patent blood sample apply technology: Upon optimization of the quantity and positions of air exhausting microporous, the blood applying speed has been obviously improved.
- With superior electrochemical property and extremely strong corrosion resistance, which is more stable and accurate and has strong anti-interference ability.
- Able to detect the blood sample temperature, HCT and ambient temperature accurately, and automatically correct the result deviations caused by above factors.
- Do not requied coding.



Specification
Blood volume | 0.8μL |
Sample type | Capillary whole blood venous whole blood |
Calibration | Plasma equivalent |
Measuring time | 5s |
Meter storage/transportation condition | -20C~55℃ |
Dimension | [103mm (L) x 60mm (W) x 24mm(H)] |
Weight | about 59g |
Power source | 2 AAA alkaline batteries |
Memory | 999 blood glucose measurement results with date and time 200 Control Solution measurement results with date and time |
Test condition | Temperature: 10℃~40℃ Relative Humidity: 10% ~ 90% RH (non-condensing) Hematocrit:20%~70% Altitude: Up to 10100 feet (3078 meters) Note: Use within specified environmental conditions only. |
Operating condition | 10℃~35C≤80% RH |
Construction | Hand-held |
Measurement units | mg/dL or mmol/L |
Measurement range | 20~600 mg/dL or 1.1~33.3mmol/L |
Test strip chemical composition | FAD glucose dehydrogenase, potassium ferricyanide, non-reactive ingredients |
Control solution chemical composition | Water, glucose, preservative, dyes, phosphate buffer, viscosity enhancing agents |
Test strip storage condition | 1℃~30℃ 10%~90%RH |
Shelf life | 10 years (estimated by test 7 times per day). During use, user should maintain the product refer to this user manual’s requirements. |